
DC Engineer III
Rackspace Technology
full-time
Posted on:
Location Type: Hybrid
Location: Seattle • Washington • United States
Visit company websiteExplore more
Salary
💰 $78,000 - $114,000 per year
About the role
- Oversee potentially high-risk projects and can handle the coordination of resources, project execution, & communication with supervision.
- Conduct routine facility walkthroughs that identify infrastructure risks, performance gaps, and assist in developing practical solutions to improve or mitigate.
- Read and understand drawings and prints, including one-liners and floor plans.
- Troubleshoot electrical and mechanical data center infrastructure, enabling the quick identification of root cause solutions to technical problems.
- Communicate technical activities relating to the facility, its assets, and their operation to relevant parties.
- Facilitate Root Cause Analysis (RCAs) to ensure the recurrence of issues or incidents are eliminated.
- Develop and document step-by-step methods of procedure (MOPs) for critical maintenance.
- Develop and document step-by-step Standard Operating Procedures (SOPs) and Emergency Operating Procedures (EOPs) to drive the consistency of operation and quickly respond to incidents to return equipment to operation.
- Supervise and manage scheduled maintenance of electrical, mechanical, life safety, and monitoring equipment. Assist in the preparation of detailed maintenance plans in accordance with Rackspace Technical Change Management guidelines.
- Oversee and be proficient with the monitoring equipment and other critical systems.
- Effectively lead Incident Management efforts in the event of system degradation/failures, communicating the status to all levels and resolving the issue in a timely fashion.
- Respond to Engineering requests with technical information for electrical power and mechanical capacity.
- Review building logs and maintenance records on an ongoing basis and undertake visual checks and tests of all electrical, mechanical, life safety, and monitoring equipment.
- Supervise external contractors undertaking specialist maintenance and inspections to ensure the quality of work is maintained.
- Adhere to company security policies and procedures, including health and safety, and local governing requirements as directed.
- Maintain meticulous 5S and housekeeping practices.
- Communicate regularly with peers regarding operational readiness and system conditions.
- Effective project management leads to the successful completion of assigned and/or shift projects.
- Performance improvement or risk mitigation leads to improved data center uptime resiliency.
- Proficient trouble-shooting and problem-solving capabilities lead to accurate and timely resolution of technical events and root cause identification.
- Detailed and accurate methods of procedure (MOP) lead to the successful completion of assigned critical maintenance.
- Detailed and effective SOPs lead to the efficient and reliable performance of the infrastructure operation.
- Following established EOPs; Engineer and assigned shift (if applicable) is able to return critical equipment to service, providing 100% customer uptime.
- Clear, concise, and accurate technical communication of facility-related events is delivered to the team.
- Effective Incident Management allows leadership to maintain confidence in the Data Center and Engineering team.
- Record keeping of activities is kept 100% up to date and accurate.
- Planned maintenances are completed within the associated window and in accordance with the predetermined process.
- Assigned Data Center engineering spaces are clean and organized, with specific areas demarcated for all movable items.
- Ability to work independently, manage priorities, and maintain a high level of attention to detail.
- Ability to prioritize work in a fast-paced, high-pressure environment. Regular logging activities are kept 100% up to date and accurate.
Requirements
- High School Diploma or regional equivalent required
- Bachelor's Degree required, preferably in a field related to the role. At the manager’s discretion, additional relevant experience may substitute degree requirement.
- 5 - 7 years of experience in the field of role required
- Intermediate knowledge of HVAC, HV and LV switch boards, Transformers, Chillers, BMS (Trend), Fire Alarms, Sprinkler systems, UPS, Lead acid batteries, Generators, PDUs, and RPPs
- Technical Acumen
Benefits
- incentive compensation opportunities in the form of annual bonuses or incentives
- equity awards
- Employee Stock Purchase Plan (ESPP)
Applicant Tracking System Keywords
Tip: use these terms in your resume and cover letter to boost ATS matches.
Hard Skills & Tools
HVACHV switch boardsLV switch boardsTransformersChillersBMSFire AlarmsSprinkler systemsUPSGenerators
Soft Skills
project managementproblem-solvingcommunicationattention to detailindependent workprioritizationleadershipcoordinationincident managementperformance improvement
Certifications
High School DiplomaBachelor's Degree